Cable
Testers
|

MTT-1055
MTT-1055 is a multifunction operation net wire tester, I can test for rank
sequence net wire one by one. It can exact determmine 10Base-T,10Base-2 Coaxila
Cable, RJ45/RJ11 Telephone Line, 258A/TIA-568A/568B and Token Ring net wire etc.
|
| Features |
MTT1055 is a multi-function integration net wire tester, it can teste for rank sequence net wire onde by one.
|
|
So it can´t any limit when test net wire standard
|
|
Through compare main engine end send indicator lamp, with corresponding terminal receive indicator lamp condition.
|
|
It can exact determine 10Base-T, 10Base-2 coaxil cable, RJ145/RJ11 telephone line, 258A/TIA-568A/568B and token ring net wire etc.
|
|
Various kind net and needlework connecting detail condition.
|
|
Work in use configuration the remote terminator.
|
|
It can test fixed cable (for instance underground, wall inside etc. covered cable), or distance main engine far the cable condition. MTT1055 setup auto and handwork two models, so it easier for test each cable continued, short circuit, break circuit, cross, eath condition etc.
|
| Index |
1. Power supply: voltage-9V DC current – 10mA |
2. Auto scan time: about 4 seconds (a eycle) |
3. Battery type: 9 volt cascade battery (6F – 22type) |
| 4. Appearance size (mm): |
main engine: 103 (L) x 62 (W) x 27(H) |
| |
terminator: 103 (L) x 30 (W) x 27(H) |
|
| 5. Weight: about 250g |
| 6. Configuration: main engime 1 pcs, remote terminator 1 pes. BNC/RJ45 transfer wire 2 pcs. |
7. Attachment: auto test wire 1 pcs. (MTT1055).BNC/BNC connect head 1 pcs. (MTT1055) |
|
| |
APPEARANCE INTRODUCTION (SEE PICTURE) |
 |
(1) RJ 45 socker (send)
(2) Manual test button
(3) Auto/ manual test switch
(4) RJ45 socket (receive)
(5) Send indicator lamp
(6) Receive indicator lamp
(7) Power switch
(8) Battery box cover (behind)
(9) RJ45 socket (receive)
(10) Receive indicator lamp
(11) Shield earth indicator lamp |
| |
|
| Operation |
ONLY USE MAIN ENGINE FOR LOOP TEST
1. TEST RJ45 ETC. CABLE
|
1-1. Will be tested net wire one end insert main engine RJ45 socket “send” socket (main engine on mark indicate placed). One end insert main engine the other RJ45 receive socket on
1-2.
Power switch placed “ON” situation
1-3.
Press off “AUTO/MANUAL” button, choice auto or manual scan model.
1-4.
When AUTO/MANUAL switch placed AUTO placed, then up line indicator lamp beginning as per sequence from left to right auto light up. If in (MANUAL) situation, then will be lighted up from up line number 1. (each press one time, move one lamp)
1-5.
With up line corresponding indicator lamp of down line the indicator lamp will light up same time.
1-6.
Read the display result form indicator lamp, it can got tested net wire the connect condition. (see test result skech map) |
TEST BNC COAXIL CABLE
2-1. Configuration BNC/RJ45 transfer wire (MTT1055) separate insert two RJ45 socket, then will be tested two ends connect to transfer wire on, will BNC cable both head connect to transfer wire both ends.
2 -2. The other steps please refer test RJ451.2-1.6 operation.
Mark: 1) BNC wire the wick wire corresponding indicator lamp 1 read,
B NC wire shield correspond indicator lamp 2 read, please refer picture 1.
2) If likeness 10BASE-2 net wire-only 2 wires condition, we suggest that your use manual sacn model for test.
| |
 |
|
| |
| |
BNC wick wire Indication |
| |
| |
| |
BNC shield wire indication |
|
REMOTE TEST
- Will cable onde insert main engine RJ45 “send” socket (whith /\ mark), another end insert remote terminator RJ45 “receive” socket.
If net wire fixed on the wall or underground, only show up jack, then you can through use transfer wire or transfer head to settle
- The other test steps please refer 1.2 – 1.6
- Read test result from remote terminator on the indicator lamp, (then on main engine the down line indicator lamp doesn´t work)
Mark: On remote terminator the indicator lamp shown result same main engine down line indicator lamp.
TEST RESULT SKETCH MAP
| 1 Continue |
|
2 nd wire connect as usual as cultine |
| 2 Open circuit |
|
2 nd wire open circuit (broken circuit) as cultline |
| 3. Short circuit |
|
Between 2 nd wire and 3 rd wire short circuit |
| 4. Across |
|
3 rd wire and 6 th witre the situation |
| 5. Earth |
|
Net wire shield connecting as usual |
|
| Attention |
1. Please confirm your use in 9 volt battery (6F-22 type) |
2. If didn´t use tester for a long time, please take out battery. |
3. Please be sure battery enough, if battery voltage lower, indicator lamp will not clear, flash or doesn´t bright and influence test resukt. |
| Warning |
Prohibit tester connect to with eletron wire on otherwise when hight voltage will damage tester.
* Any renew or improve of the products will not be adviced
|
|

|
|
|